Liquid-Cooled Eddy Current Equipment - Specifications

 
     

   

Home
Back (up)
Contact us
Contents
Search
-------------------------------
Data Electronics
Load Charts
Prices & Models

Land & Sea

(603) 226-DYNO

Click to Dynamometer Comparisons page.*Absorber capacities are RPM dependant. Water cooled absorbers require a minimum water flow of 1 g.p.m. @ 30+ p.s.i. for every 20 continuous Hp.

"Call Land & Sea, Inc. at (603) 329-5645 for approximate power limits of specific configurations."




 
Click to Absorber Load Charts page.

Optional DYNOmite Data-Acquisition Computer:

Expandable, surface mount, board system runs on 120-volt 60-Hz AC, 240-volt 50-Hz AC, or 12-volt DC
“Pro” PC based 28, 56 or 112+ channel capable board sets, require DYNO-MAX software
“Lite” 3-channel (upgradeable to “Pro” above)
Optional portable “Pro” 28-channel capable handheld with 168-character LCD & keypad
Up to 1,000 recordings per second (per channel)
Quick disconnect data harness
Non-volatile set-up memory
Rechargeable back-up battery option
Captures over 1-hour duration test runs
Real time and data playback displays
Observed and SAE corrected reports
Smart Record” automated recorder triggering
RS232 or USB output to optional printer or PC with DYNO-MAX software option 

Torque Transducer:

Type, performance, range, etc. vary with each application; call for exact specifications
S-beam load cells with full bridge strain gauges
Environmentally sealed
½% of full scale typical accuracy
Semi-automatic zero offset calibration
Temperature compensated
Optional wireless rotary-torque transducers available (see DYNOmite On-Board Dynamometer literature for details)

Hp, Torque, and RPM Capacity:

*Actual are RPM dependent.
#75 up to 75 Hp* 
#150 up to 150 Hp* 
#200 up to 200 Hp* 
#400 up to 400 Hp*
#600 up to 650 Hp*
#1200 up to 1,200 Hp*
Hp options range from ¼ to over 10,000
Torque options from ¼ to over 5,000 lb-ft
RPM options from 500 to over 30,000

Engine Tachometer:

0 - 32,000+ RPM LCD display
0 - 128,000+ RPM via DYNO-MAX
RPM pulse type is selectable from ½ to 240 pulses per revolution
Quartz crystal calibrated
Magnetic RPM pick-up

Load Control and Power Supply:

Electronic Load Control & Power Supply
120-volt 60-Hz AC @ 15-amp, 240-volt 60-Hz AC @ 30-amp), 240-volt 50-Hz AC @ 15-amp (or 30-amp), or 12-volt DC @ 60-amp input
Optional Electronic Throttle Controller

Liquid-Cooled Eddy-Current Absorbers:

Liquid Cooling - Standard
#75 single rotor - uses 96 or 12-volt DC supply
#150 dual rotor - uses 96 or 192-volt DC supply
#200 single rotor - uses 96 or 12-volt DC supply
#400 dual rotor - uses 96-volt or 192-volt DC supply
#600 - single rotor - uses 96-volt DC supply
#1,200 - dual rotor - uses 96 or 192-volt DC supply

Engine Test Stand Options:

Inertia independent reaction torque cradle type
Friction independent reduction drive
Load cell over-travel protection
Instrument bearing trunnions

Approximate Dimensions and Weight:

#75 liquid-cooled eddy-current absorber (only)
    14"W x 10"L x 18"H - 200 pounds
#150 liquid-cooled eddy-current absorber (only)
    14"W x 15"L x 18"H - 350 pounds
#200 liquid-cooled eddy-current absorber (only)
    20"W x 18"L x 26"H - 400 pounds
#400 liquid-cooled eddy-current absorber (only)
    20"W x 27"L x 26"H - 550 pounds
#600 liquid-cooled eddy-current absorber (only)
    32"W x 28"L x 40"H - 1100 pounds
#1200 liquid-cooled eddy-current absorber (only)
    32"W x 42"L x 40"H - 2000 pounds

Data Collection Options:

See DYNOmite Dynamometer Conversion Systems section or separate Dynamometer Accessories Catalog for options.

Other Options:

See separate Dynamometer Accessories Catalog


DYNO-mite dynamometer
For DYNO-mite Dynamometer technical assistance - phone or e-mail: sales@land-and-sea.com

© 08 Aug 2010  Land & Sea, Inc. 25 Henniker Street; Concord, NH 03301-8528 USA   
 +1-603-226-DYNO




land and sealand and seaHome Back (up) Contents Search