Eddy
Current Equipment - Specifications
|
| |
| |
*Absorber
capacities are RPM dependant. Water cooled absorbers
require a minimum water flow of 1 g.p.m. @ 30+ p.s.i. for every 20 continuous
Hp.
"Call Land & Sea, Inc. at (603) 329-5645 for approximate power limits of
specific configurations."
|
|
|
Optional DYNOmite Data-Acquisition Computer:
Expandable, surface mount, board system runs on 120-volt
60-Hz AC, 240-volt 50-Hz AC, or 12-volt DC
“Pro” PC based 28, 56 or 112+ channel capable board sets, require
DYNO-MAX software
“Lite” 3-channel (upgradeable to “Pro” above)
Optional portable “Pro” 28-channel capable handheld with 168-character
LCD & keypad
Up to 1,000 recordings per second (per channel)
Quick disconnect data harness
Non-volatile set-up memory
Rechargeable back-up battery option
Captures over 1-hour duration test runs
Real time and data playback displays
Observed and SAE corrected reports
“Smart Record” automated recorder triggering
RS-232 or USB output to optional printer or PC with DYNO-MAX 2000 software
option
Torque Transducer:
Type, performance, range, etc. vary with each application;
call for exact specifications
S-beam load cells with full bridge strain gauges
Environmentally sealed
½% of full scale typical accuracy
Semi-automatic zero offset calibration
Temperature compensated
Optional wireless rotary-torque transducers available (see DYNOmite On-Board
Dynamometer literature for details)
Hp, Torque, and RPM Capacity:
*Actual air-cooled eddy current capacities are RPM and absorber
temperature dependent. Initial cold rotor torque and Hp capacities are approximately
twice the hot rotor Hp capacities
shown below (taken after
running 10 minutes, at
full load, in a room temperature
environment). Continuous ratings will be approximately
50% of these hot values.
“Micro” up to 1 Hp hot (¼ Hp min.)*
“Mini” up to 3 Hp hot (¾
Hp min.)*
#20 up to 20 Hp hot *
#100 up to 100 Hp hot *